Outdoorlink Controllers

Outdoorlink offers multiple controllers for different applications. Compare the differences below or contact us to decide which model is best for your project at sales@outdoorlinkinc.com or call (256) 885-9768 ext. 3.

Controller Comparison Matrix

All controllers include standard features for Scheduling, Rebooting, Alarm Notifications, Proof of Performance, Power Readings and Mapping. 

SmartLink Vantage Controller for Virtual Content Verification
SL-4-AC
Device Management
1-4
Power Compatible
AC
Outside Dimensions
10.5 x 10.7 x 3.4
Input Voltage
120-277 Vac @ 60Hz
Max Input Current
24 A per line
Max Output Power
16 A per relay @ 50°C
14 A per relay @ 70°C
Operating Temp.
-40°C to 70°C
Special Features
Open API, Mapping, Rebooting, Scheduling, Alarms, Power Readings, Proof of Performance, Maintenance Log, Intrusion Detection
Alarm Notifications
Loss of Power, Power Restore, Tamper, Bulb Outage, No Current/Power, Bad Neutral
Recommended for
Area Lighting, Billboard Illumination, Digital Displays, Shelter Ammenities, Field Lighting, Media Players, Modem/Routers
Specification
SL-4-DC
Device Management
1-4
Power Compatible
DC
Outside Dimensions
10.5 x 10.7 x 3.4
Input Voltage
11-28 Vdc
Max Input Current
30 A per line
Max Output Power
7.5A per relay
Operating Temp.
-40°C to 75°C
Special Features
Open API, Mapping, Rebooting, Scheduling, Alarms, Power Readings, Proof of Performance, Maintenance Log, Intrusion Detection
Alarm Notifications
Loss of Power, Power Restore, Tamper, Bulb Outage, No Current/Power
Recommended for
Area Lighting, Billboard Illumination, Digital Displays, Shelter Ammenities, Field Lighting, Media Players, Modem/Routers
Specification
302i
Device Management
1-4
Power Compatible
AC
Outside Dimensions
10.5 x 10.7 x 3.4
Input Voltage
230 Vac @ 50 or 60Hz
Max Input Current
25 A per line
Max Output Power
10 A per relay
Operating Temp.
-40°C to 70°C
Special Features
Open API, Mapping, Rebooting, Scheduling, Alarms, Power Readings, Proof of Performance, Maintenance Log, Intrusion Detection
Alarm Notifications
Loss of Power, Power Restore, Tamper, Bulb Outage, No Current/Power
Recommended for
Area Lighting, Billboard Illumination, Digital Displays, Shelter Ammenities, Field Lighting, Media Players, Modem/Routers
Specification
SL-2-DC
Device Management
1-2
Power Compatible
DC
Outside Dimensions
5.82 x 3.3 x 0.65
Input Voltage
5-30 Vdc
Max Input Current
4 A per relay
Max Output Power
4 A per relay
Operating Temp.
0°C to 65°C
Special Features
Open API, Mapping, Rebooting, Scheduling, Alarms, Power Readings, Proof of Performance, Maintenance Log, Voltage Threshold Triggers, Dimming
Alarm Notifications
Loss of Power, Low Power, Power Restore, No Power, Offline, Low Voltage, High Voltage
Recommended for
Solar Lighting, Advertising Shelters, Digital Real-Time Displays, Media Players, WIFI Routers, USB Charging Ports, Door Locks
Specification
SL-Vantage
Device Management
1-2
Power Compatible
DC
Outside Dimensions
5.8 x 3.3 x 0.65
Input Voltage
8-28 Vdc
Max Input Current
4 A per relay
Max Output Power
4 A per relay
Operating Temp.
0°C to 60°C
Special Features
Open API, Mapping, Rebooting, Scheduling, Alarms, Power Readings, Proof of Performance, Screen Capture
Alarm Notifications
Loss of Power, No Power, No Display Detected, No Video Input, No Content on Screen, Stuck Video, No Sensor
Recommended for
LCD Digital Displays with Media Players
Specification

Frequently Asked Questions

How Many Controllers Do I Need?

Controllers have 1-4 relay outputs, and can manage 1-8 assets, if some assets are doubled per relay.  Contact us to talk about your application and we'll confirm the model that provides the most value (256) 885-9768 ext. 3.

Can I Add More Assets Later to the Same Controller?

Yes. A second, third or fourth asset can be managed from one controller depending on the model selected.

How Do The Controllers Work?

The controller is hardwired to devices, such as lighting and digital signage, and accessible through a SIM card inside each unit.  This enables two-way communication to and from the controller and the devices it is wired to.  